Validation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone

The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA's Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and aircraft measurements. TES measurements also have sensitivity throughout the stratosphere, and therefore TES ozone profiles can be integrated to determine the total and stratospheric column in addition to the tropospheric column ozone values. In this work we compare the ozone in the stratosphere measured by TES to observations from the Microwave Limb Sounder (MLS) instrument in order to show the quality of the TES measurements in the stratosphere. We also compare the determination of a total column value for ozone based on the TES profiles to the column measured by the Ozone Monitoring Instrument (OMI). The TES tropospheric ozone column value is also calculated from the TES profiles and compared with column values determined from ozonesonde data. Column measurements are useful because the errors are markedly reduced from errors at the profile levels and can be used to assess both biases and quality of the TES ozone retrievals. TES observations of total or partial column ozone compare well with the other instruments but tend toward higher values than the other measurements. Specifically, TES is higher than OMI by ∼10 Dobson units (DU) for the total ozone column. TES measures higher values in the stratosphere (above 100 hPa) by ∼3 DU and measures higher ozone column values (∼4 DU) in the troposphere than ozonesondes. While the strength of the TES nadir ozone product is the vertical resolution it provides in the troposphere, a tropospheric column value derived from TES have utility in analyses using or validating tropospheric ozone residual products.

To Access Resource:

Questions? Email Resource Support Contact:

  • opensky@ucar.edu
    UCAR/NCAR - Library

Resource Type publication
Temporal Range Begin N/A
Temporal Range End N/A
Temporal Resolution N/A
Bounding Box North Lat N/A
Bounding Box South Lat N/A
Bounding Box West Long N/A
Bounding Box East Long N/A
Spatial Representation N/A
Spatial Resolution N/A
Related Links N/A
Additional Information N/A
Resource Format PDF
Standardized Resource Format PDF
Asset Size N/A
Legal Constraints

An edited version of this paper was published by AGU. Copyright 2008 American Geophysical Union.


Access Constraints None
Software Implementation Language N/A

Resource Support Name N/A
Resource Support Email opensky@ucar.edu
Resource Support Organization UCAR/NCAR - Library
Distributor N/A
Metadata Contact Name N/A
Metadata Contact Email opensky@ucar.edu
Metadata Contact Organization UCAR/NCAR - Library

Author Osterman, G.
Kulawik, S.
Worden, Helen M.
Richards, N.
Fisher, B.
Eldering, A.
Shephard, M.
Froidevaux, L.
Labow, G.
Luo, M.
Herman, R.
Bowman, Kenneth
Thompson, A.
Publisher UCAR/NCAR - Library
Publication Date 2008-05-07T00:00:00
Digital Object Identifier (DOI) Not Assigned
Alternate Identifier N/A
Resource Version N/A
Topic Category geoscientificInformation
Progress N/A
Metadata Date 2025-07-17T15:58:13.745512
Metadata Record Identifier edu.ucar.opensky::articles:6569
Metadata Language eng; USA
Suggested Citation Osterman, G., Kulawik, S., Worden, Helen M., Richards, N., Fisher, B., Eldering, A., Shephard, M., Froidevaux, L., Labow, G., Luo, M., Herman, R., Bowman, Kenneth, Thompson, A.. (2008). Validation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone. UCAR/NCAR - Library. https://n2t.org/ark:/85065/d7mp53g1. Accessed 11 August 2025.

Harvest Source