A tethered-balloon PTRMS sampling approach for surveying of landscape-scale biogenic VOC fluxes
Landscape-scale fluxes of biogenic gases were surveyed by deploying a 100 m Teflon tube attached to a tethered balloon as a sampling inlet for a fast-response proton-transfer-reaction mass spectrometer (PTRMS). Along with meteorological instruments deployed on the tethered balloon and a 3 m tripod and outputs from a regional weather model, these observations were used to estimate landscape-scale biogenic volatile organic compound fluxes with two micrometeorological techniques: mixed layer variance and surface layer gradients. This highly mobile sampling system was deployed at four field sites near Barcelona to estimate landscape-scale biogenic volatile organic compound (BVOC) emission factors in a relatively short period (3 weeks).
document
http://n2t.net/ark:/85065/d7542pj8
eng
geoscientificInformation
Text
publication
2016-01-01T00:00:00Z
publication
2014-07-23T00:00:00Z
Copyright Author(s) 2014. This work is distributed under the Creative Commons Attribution 3.0 License
None
OpenSky Support
UCAR/NCAR - Library
PO Box 3000
Boulder
80307-3000
name: homepage
pointOfContact
OpenSky Support
UCAR/NCAR - Library
PO Box 3000
Boulder
80307-3000
name: homepage
pointOfContact
2023-08-18T18:55:23.817974