Comparison between ozone column depths and methane lifetimes computed by one- and three-dimensional models at different atmospheric O2 levels

Recently, Cooke et al. (Cooke et al. 2022 R. Soc. Open Sci. 9, 211165. ()) used a three-dimensional coupled chemistry-climate model (WACCM6) to calculate ozone column depths at varied atmospheric O-2 levels. They argued that previous one-dimensional (1-D) photochemical model studies, e.g. Segura et al. (Segura et al. 2003 Astrobiology 3, 689-708. ()), may have overestimated the ozone column depth at low pO(2), and hence also overestimated the lifetime of methane. We have compared new simulations from an updated version of the Segura et al. model with those from WACCM6, together with some results from a second three-dimensional model. The discrepancy in ozone column depths is probably due to multiple interacting parameters, including H2O in the upper troposphere, lower boundary conditions, vertical and meridional transport rates, and different chemical mechanisms, especially the treatment of O-2 photolysis in the Schumann-Runge (SR) bands (175-205 nm). The discrepancy in tropospheric OH concentrations and methane lifetime between WACCM6 and the 1-D model at low pO(2) is reduced when absorption from CO2 and H2O in this wavelength region is included in WACCM6. Including scattering in the SR bands may further reduce this difference. Resolving these issues can be accomplished by developing an accurate parametrization for O-2 photolysis in the SR bands and then repeating these calculations in the various models.

To Access Resource:

Questions? Email Resource Support Contact:

  • opensky@ucar.edu
    UCAR/NCAR - Library

Resource Type publication
Temporal Range Begin N/A
Temporal Range End N/A
Temporal Resolution N/A
Bounding Box North Lat N/A
Bounding Box South Lat N/A
Bounding Box West Long N/A
Bounding Box East Long N/A
Spatial Representation N/A
Spatial Resolution N/A
Related Links

Related Dataset #1 : Supplementary material from "Comparison between ozone column depths and methane lifetimes computed by one- and three-dimensional models at different atmospheric O<sub>2</sub> levels"

Related JournalArticle #1 : Comparison Between Ozone Column Depths and Methane Lifetimes Computed by 1-D and 3-D Models at Different Atmospheric O<sub>2</sub> Levels

Additional Information N/A
Resource Format PDF
Standardized Resource Format PDF
Asset Size N/A
Legal Constraints

Copyright author(s). This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.


Access Constraints None
Software Implementation Language N/A

Resource Support Name N/A
Resource Support Email opensky@ucar.edu
Resource Support Organization UCAR/NCAR - Library
Distributor N/A
Metadata Contact Name N/A
Metadata Contact Email opensky@ucar.edu
Metadata Contact Organization UCAR/NCAR - Library

Author Ji, A.
Kasting, J.
Cooke, G.
Marsh, Daniel
Tsigaridis, K.
Publisher UCAR/NCAR - Library
Publication Date 2023-05-03T00:00:00
Digital Object Identifier (DOI) Not Assigned
Alternate Identifier N/A
Resource Version N/A
Topic Category geoscientificInformation
Progress N/A
Metadata Date 2025-07-11T15:18:10.397144
Metadata Record Identifier edu.ucar.opensky::articles:26318
Metadata Language eng; USA
Suggested Citation Ji, A., Kasting, J., Cooke, G., Marsh, Daniel, Tsigaridis, K.. (2023). Comparison between ozone column depths and methane lifetimes computed by one- and three-dimensional models at different atmospheric O2 levels. UCAR/NCAR - Library. https://n2t.org/ark:/85065/d7pr80zh. Accessed 02 August 2025.

Harvest Source