Comparisons of line-of-sight water vapor observations using the Global Positioning System and a pointing microwave radiometer

Line-of-sight measurements of integrated water vapor from a global positioning system (GPS) receiver and a microwave radiometer are compared. These two instruments were collocated at the central facility of the Department of Energy’s Atmospheric Radiation Measurement Program’s Southern Great Plains region, near Lamont, Oklahoma. The comparison was made using 47 days of observations in May and June of 2000. Weather conditions during this time period were variable with total integrated water vapor ranging from less than 10 to more than 50 mm. To minimize errors in the microwave radiometer observations, observations were compared during conditions when the liquid water measured by the radiometer was less than 0.1 mm. The linear correlation of the observations between the two instruments is 0.99 with a root-mean-square difference of the GPS water vapor to a linear fit of the microwave radiometer of 1.3 mm. The results from these comparisons are used to evaluate the ability of networks of GPS receivers to measure instantaneous line-of-sight integrals of water vapor. A discussion and analysis is provided regarding the additional information of the water vapor field contained in these observations compared to time- and space-averaged zenith and gradient measurements.

To Access Resource:

Questions? Email Resource Support Contact:

  • opensky@ucar.edu
    UCAR/NCAR - Library

Resource Type publication
Temporal Range Begin N/A
Temporal Range End N/A
Temporal Resolution N/A
Bounding Box North Lat N/A
Bounding Box South Lat N/A
Bounding Box West Long N/A
Bounding Box East Long N/A
Spatial Representation N/A
Spatial Resolution N/A
Related Links N/A
Additional Information N/A
Resource Format PDF
Standardized Resource Format PDF
Asset Size N/A
Legal Constraints

Copyright 2003 American Meteorological Society (AMS). Permission to use figures, tables, and brief excerpts from this work in scientific and educational works is hereby granted provided that the source is acknowledged. Any use of material in this work that is determined to be "fair use" under Section 107 or that satisfies the conditions specified in Section 108 of the U.S. Copyright Law (17 USC, as revised by P.L. 94-553) does not require the Society's permission. Republication, systematic reproduction, posting in electronic form on servers, or other uses of this material, except as exempted by the above statements, requires written permission or license from the AMS. Additional details are provided in the AMS Copyright Policies, available from the AMS at 617-227-2425 or amspubs@ametsoc.org. Permission to place a copy of this work on this server has been provided by the AMS. The AMS does not guarantee that the copy provided here is an accurate copy of the published work.


Access Constraints None
Software Implementation Language N/A

Resource Support Name N/A
Resource Support Email opensky@ucar.edu
Resource Support Organization UCAR/NCAR - Library
Distributor N/A
Metadata Contact Name N/A
Metadata Contact Email opensky@ucar.edu
Metadata Contact Organization UCAR/NCAR - Library

Author Braun, John
Rocken, Christian
Liljegren, James
Publisher UCAR/NCAR - Library
Publication Date 2003-05-01T00:00:00
Digital Object Identifier (DOI) Not Assigned
Alternate Identifier N/A
Resource Version N/A
Topic Category geoscientificInformation
Progress N/A
Metadata Date 2023-08-18T19:04:47.321790
Metadata Record Identifier edu.ucar.opensky::articles:17346
Metadata Language eng; USA
Suggested Citation Braun, John, Rocken, Christian, Liljegren, James. (2003). Comparisons of line-of-sight water vapor observations using the Global Positioning System and a pointing microwave radiometer. UCAR/NCAR - Library. http://n2t.net/ark:/85065/d7w09766. Accessed 14 February 2025.

Harvest Source