Applicability of condensation particle counters to measure atmospheric clusters

This study presents an evaluation of a pulse height condensation particle counter (PH-CPC) and an expansion condensation particle counter (E-CPC) in terms of measuring ambient and laboratory-generated molecular and ion clusters. Ambient molecular cluster concentrations were measured with both instruments as they were deployed in conjunction with an ion spectrometer and other aerosol instruments in Hyytiälä, Finland at the SMEAR II station between 1 March and 30 June 2007. The observed cluster concentrations varied and ranged from some thousands to 100 000 cm⁻³. Both instruments showed similar (within a factor of ~5) concentrations. An average size of the detected clusters was approximately 1.8 nm. As the atmospheric measurement of sub 2-nm particles and molecular clusters is a challenging task, we conclude that most likely we were unable to detect the smallest clusters. Nevertheless, the reported concentrations are the best estimates to date for minimum cluster concentrations in a boreal forest environment.

To Access Resource:

Questions? Email Resource Support Contact:

  • opensky@ucar.edu
    UCAR/NCAR - Library

Resource Type publication
Temporal Range Begin N/A
Temporal Range End N/A
Temporal Resolution N/A
Bounding Box North Lat N/A
Bounding Box South Lat N/A
Bounding Box West Long N/A
Bounding Box East Long N/A
Spatial Representation N/A
Spatial Resolution N/A
Related Links N/A
Additional Information N/A
Resource Format PDF
Standardized Resource Format PDF
Asset Size N/A
Legal Constraints

Copyright Authors 2008. This work is distributed under the Creative Commons Attribution 3.0 License.


Access Constraints None
Software Implementation Language N/A

Resource Support Name N/A
Resource Support Email opensky@ucar.edu
Resource Support Organization UCAR/NCAR - Library
Distributor N/A
Metadata Contact Name N/A
Metadata Contact Email opensky@ucar.edu
Metadata Contact Organization UCAR/NCAR - Library

Author Sipilä, M.
Lehtipalo, K.
Kulmala, M.
Petäjä, Tuukka
Junninen, H.
Aalto, P.
Manninen, H.
Kyrö, E.
Asmi, E.
Riipinen, I.
Curtius, J.
Kürten, A.
Borrmann, S.
O'Dowd, C.
Publisher UCAR/NCAR - Library
Publication Date 2008-07-25T00:00:00
Digital Object Identifier (DOI) Not Assigned
Alternate Identifier N/A
Resource Version N/A
Topic Category geoscientificInformation
Progress N/A
Metadata Date 2025-07-17T15:56:56.909647
Metadata Record Identifier edu.ucar.opensky::articles:6349
Metadata Language eng; USA
Suggested Citation Sipilä, M., Lehtipalo, K., Kulmala, M., Petäjä, Tuukka, Junninen, H., Aalto, P., Manninen, H., Kyrö, E., Asmi, E., Riipinen, I., Curtius, J., Kürten, A., Borrmann, S., O'Dowd, C.. (2008). Applicability of condensation particle counters to measure atmospheric clusters. UCAR/NCAR - Library. https://n2t.org/ark:/85065/d71z44mb. Accessed 08 August 2025.

Harvest Source